electricity, natural gas, GT, NT, at power plant/AU U - XML file viewer


General Information

Nameelectricity, natural gas, GT, NT, at power plant/AU U
Infrastructure Process
Reference quantity
category
Sub Category
Included Processes
General CommentThis is a default entry as we cannot create persons without company information for the EcoEditor.
CountryGLO
Geography
TechnologyAverage technology
Time Period

Product Flows

Flow IDNameMean ValueUnitGeneral Comment
1electricity, natural gas, GT, NT, at power plant/AU U1.000000E+0MWh

Input Processes

NameUnitAmountMathematical relationComment
tap water, at user/RER U/adapted/AU Ukg8.000000E+1Water*1000
Treatment, sewage, to wastewater treatment, class 3/CH U/AusSD Um37.300443E-2WaterTotal*Water_to_WWT
natural gas, high pressure, Northern Territory/AU Ut2.640355E-1m_gasperMWh
Gas power plant, 300MWe/GLO/I U/AusSD Up4.590000E-8

Output Processes

NameUnitAmountMathematical relationComment

Flows from the environment

Flow IDNameMean ValueUnitGeneral Comment

Emissions to air

Flow IDNameMean ValueUnitGeneral Comment

Emissions to water

Flow IDNameMean ValueUnitGeneral Comment

Emissions to soil

Flow IDNameMean ValueUnitGeneral Comment

Non-material emissions

Flow IDNameMean ValueUnitGeneral Comment

Parameters

VariableNameAmountMathematicalRelationComment
EF_CO25.165882E+1
Gen_eff2.718208E-1Gen_eff_ALCI*NGAF_Adjust
O2forCO5.710000E-1
Water8.000000E-2
ED_NaturalGas5.016000E+1
EF_NOx2.448235E+1
EF_N2O9.700000E-2
EF_SO22.329412E+1
O2forCO27.270000E-1
Gen_eff_ALCI2.560000E-1
EF_NMVOC1.958824E+0
NGAF1.000000E+0
EF_CH44.511765E+0
EF_CO1.596471E+2
O2forNO23.480000E-1
GJ_FuelperMWH1.324402E+13.6/Gen_eff
H_in_Gas2.500000E-1
NGAF_Adjust1.061800E+0
O2_req4.987121E+2(GJ_FuelperMWH*EF_CO2*O2forCO2)+(((GJ_FuelperMWH*EF_CO*O2forCO)+(GJ_FuelperMWH*EF_NOx*O2forNO2))/1000)
WaterTotal1.460089E-1Water+H_in_Gas*m_gasperMWh
m_gasperMWh2.640355E-1GJ_FuelperMWH/ED_NaturalGas
Water_to_WWT5.000000E-1