Electricity, low voltage {AU-NT}| market for electricity, low voltage | AusLCI, U

Unit process v00.00.000

Remark: Distribution of electricity including distribution losses. GeographyNorthen Territory, Australia. Technology: Current Version: 1.0 Included processes start:Process begins withthe delivery of high voltage power into the distribution network Inlcuded processes end: Process ends with the delivery of low voltage <= 415 V Excluded processes:Heat emissions not included. Start date:2011-07-0 End date:2102-06-30 is data valid for entire period: false Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Generator/publicator: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU

Sector
Energy
Contributor
—
Last updated
07 Apr 2013
Reference ID
11758ca3-4c95-3517-bb35-c4a994e1b840

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Electricity, low voltage {AU-NT}| market for electricity, low voltage | AusLCI, U
Sampling procedure
Sulfur hexafluoride and distribution infracstructure taken from ecoinvent.
Creation date
07 Apr 2013
Is copyright protected
No
Is infrastructure process
No
Tags
energy
Sources
Energy Gas Australia 2018/2018/Australian Energy Council.

Product outputs

Flow AmountUnitComment
Electricity, low voltage {AU-NT}| market for electricity, low voltage | AusLCI, U 1.0 kWh —

Technical inputs

Flow AmountUnitComment
Distribution network, electricity, low voltage {GLO}| market for distribution network, electricity, low voltage | Cut-off, U 0.000000294 km (3,1,4,5,3,5); based on consumption statistics
Electricity, high voltage {AU-NT}| market for electricity, high voltage | AusLCI, U 1.0606703436571914 kWh High voltage input including distribution loss.
Sulfur hexafluoride, liquid {RoW}| market for sulfur hexafluoride, liquid | Cut-off, U 0.00000000459 kg (1,1,2,5,1,3); assumed with data of German statistics

Elementary flow outputs

Flow CompartmentSub-compartment AmountUnitComment
Energy losses in electricty distribution Non material emissions— 0.06067034365719137 kWh —
Sulfur hexafluoride Emission to airunspecified 0.00000000459 kg (1,1,2,5,1,3); assumed with data of German statistics

Parameters

NameValueFormulaDescription
Distribution_loss 0.0572 — State specific low voltage distribution loss factor derived from AEMO FY21-22 data