Electricity, high voltage {AU-NSW}| market for electricity, high voltage | AusLCI, U
Unit process v00.00.000
- Sector
- Energy
- Contributor
- —
- Last updated
- 30 Dec 1899
- Reference ID
42877ef9-cadb-35c3-85c1-8c20cbb032c2
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity, high voltage {AU-NSW}| market for electricity, high voltage | AusLCI, U
- Sampling procedure
- —
- Creation date
- 30 Dec 1899
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Energy Gas Australia 2018/2018/Australian Energy Council.
Energy in Australia 2011/2011/ABARE
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, high voltage {AU-NSW}| market for electricity, high voltage | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at powerplant {AU-NSW}| electricity production mix | AusLCI, U | 1.0463534581981793 | kWh | — |
| Transmission network, electricity, high voltage {GLO}| market for transmission network, electricity, high voltage | Cut-off, U | 0.00000000844 | km | — |
| Transmission network, long-distance {GLO}| market for transmission network, long-distance | Cut-off, U | 0.000000000317 | km | — |
Elementary flow inputs
| Flow | Sub-compartment | Amount | Unit | Comment |
|---|---|---|---|---|
| Occupation, urban, green areas | — | 0.039761431411530816 | m2*a | — |
Elementary flow outputs
| Flow | Compartment | Sub-compartment | Amount | Unit | Comment |
|---|---|---|---|---|---|
| Dinitrogen monoxide | Emission to air | low population density | 0.000005 | kg | — |
| Energy losses in electricty transmission | Non material emissions | — | 0.0443 | kWh | — |
| Ozone | Emission to air | low population density | 0.0000045 | kg | — |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| Width | 20.0 | — | (5,5,5,5,na,na)[m] Estimated Width occupied by the power line NOT CHANGED |
| E_Total_Aus | 230374.0 | — | (1,1,1,1,1,na)[GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5 |
| TL_Total_Aus | 458000000.0 | — | (1,1,1,1,1,na)[m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia NOT CHANGED |
| Transmission_Loss | 0.0443 | — | Based on AEMO NEM Marginal Loss Factors report FY22-23 and EGA Appendix 1 Principal Power stations in Australia 2022-23 |
| Occupation_m2a | 0.039761431411530816 | (TL_Total_Aus*Width)/E_Total_Aus/1000000 | [m2a] Average area occupied for transmission per GWh/100000 to get to kWhs |