NSW electricity mix 2017 data was inputted into Excel. Two categories of renewables identified, scaling renewables (SGas, Solar, and Wind) and non-scaling (Hydro, Bagasse, Biomass, BLiquor, Heat Pump, and Lgas). Gap identified at 2050 by sum of non-renewables at 2020 values. Scaling renewable percentage of gap was calculated for 2050. Linear model in Excel was used to calculate the increase per year for scaling renewables 2050 values and non-renewable sources to decrease to 0 by 2050. Non-scaling renewables were kept constant from 2020 to 2050. Average determined for 2050 and 2080, values used in parameters within electricity mix 2050 NSW and electricity mix 2080 NSW processes.
- Sector
- Energy
- Contributor
- —
- Last updated
- 30 Dec 1899
- Reference ID
56edd877-a470-393c-9e03-191132a122a9
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity mix, 2050 New South Wales {AU}|_Obsolete | AusLCI, U
- Sampling procedure
- —
- Creation date
- 30 Dec 1899
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Energy Gas Australia 2018/2018/Australian Energy Council.
Energy in Australia 2011/2011/ABARE
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity mix, 2050 New South Wales {AU}|_Obsolete | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U | 0.0012321333997075156 | kWh | — |
| Electricity, black coal NSW, at power plant {AU}| | AusLCI, U | 0.4198274236443381 | kWh | — |
| Electricity, high voltage {AU}| electricity production, oil | Cut-off, U | 0.0005275043239736351 | kWh | — |
| Electricity, high voltage {AU}| electricity production, wind, >3MW turbine, onshore | Cut-off, U | 0.2108283458647782 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.004812154710195714 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.00702869214550002 | kWh | — |
| Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U | 0.004427355478805104 | kWh | — |
| Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U | 0.002103192685089647 | kWh | — |
| Electricity, high voltage {RoW}| electricity production, hydro, reservoir, non-alpine region | Cut-off, U | 0.0441850349383948 | kWh | — |
| Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U | 0.2851738868943539 | kWh | — |
| Electricity, natural gas, CC, at power plant {AU}| | AusLCI, U | 0.012545047554520291 | kWh | — |
| Electricity, natural gas, GT, at power plant {AU}| | AusLCI, U | 0.004673426268510449 | kWh | — |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| E_Hydro | 2950.0 | — | [GWh] Total production of electricity from Hydro in NSW in 2017. EGA Australia 2018 Table 2.6 equates to 2.8% of supply 2017 value used for 2050 calculations, remains constant. |
| E_BlackCoal | 28029.64627 | — | [GWh] Total production of electricity from Black coal in NSW in 2017. EGA Australia 2018 Table 2.6 equates to 76.1% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_HeatPump | 82.263 | — | [GWh] Total production of electricity from Heat pump in NSW in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.1% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_Wind | 14075.88839 | — | [GWh] Total production of electricity from Wind in NSW in 2017. EGA Australia 2018 Table 2.6 equates to 0.6% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value. |
| E_CSMGT | 0.640305 | — | [GWh] Total production of electricity from CSM GT in Australia in 2017. EGA Australia 2018 Table 2.6 equates to 0% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| NRE_Total_NSW | 29216.822435350005 | E_BlackCoal+E_Oil+E_GTurbine+E_Gcombined+E_CSMGT+E_CSMCC | [GWh] Total production of electricity from non-renewable resources in New South Wales in 2010 |
| TL_Total_Aus | 458000000.0 | — | [m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia |
| E_SGas | 469.2684267 | — | [GWh] Total production of electricity from Sewage gas in NSW in 2017. EGA Australia 2018 Table 2.11-12 equates to 0% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value. |
| E_Total_NSW | 66764.68637205 | RE_Total_NSW+NRE_Total_NSW | [GWh] Total production of electricity in New South Wales in 2010 |
| E_Bagasse | 140.419 | — | [GWh] Total production of electricity from Bagasse in NSW in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.1% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_GTurbine | 312.0198391 | — | [GWh] Total production of electricity from Gas turbine in NSW in 2017. EGA Australia 2018 Table 2.5 equates to 0.4% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_CSMCC | 1.731195 | — | [GWh] Total production of electricity from CSM CC in Australia in 2017. EGA Australia 2018 Table 2.6 equates to 0% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Solar | 19039.54512 | — | [GWh] Total production of electricity from Solar in NSW in 2017. Department of the Environment and Energy, Australian Energy Statistics, Table O, August 2018, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value |
| E_BLiquor | 173.607 | — | [GWh] Total production of electricity from Black liquor in NSW in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.1% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_Total_Aus | 230374.0 | — | [GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5 |
| RE_Total_NSW | 37547.8639367 | E_Hydro+E_Biomass+E_Bagasse+E_heatpump+E_BLiquor+E_Lgas+E_SGas+E_Wind+E_solar | [GWh] Total production of electricity from renewable resources in New South Wales in 2010 |
| E_GCombined | 837.5661655 | — | [GWh] Total production of electricity from Combined cycle in NSW in 2017. EGA Australia 2018 Table 2.5 equates to 4.7% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Lgas | 321.282 | — | [GWh] Total production of electricity from Landfill gas in NSW in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.3% of supply, Value used for 2050 calculations and remains constant |
| E_Oil | 35.21866075 | — | [GWh] Total production of electricity from Oil products in NSW in 2017. EGA Australia 2018 Table 2.6 equates to 0% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Biomass | 295.591 | — | [GWh] Total production of electricity from Biomass in NSW in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.1% of supply, 2017 value used for 2050 calculations, remains constant. |