Pumping, irrigation, 10m pumping depth, 50% electricity, NSW {AU}| | AusLCI, U

Unit process Australia v00.00.000

Included processes: Include infrastructure, fuel production and use of pump for irrigation. Remark: This inventory has been developed as part of the AusAgLCI initiative funded by a partnership of Australian Research and Development Corporations (RIRDC, CRDC, GRDC, SRDC, HAL, MLA, DA, FWPA) and Research Agencies (CSIRO, USQ and Q DAFF), with technical support from Life Cycle Strategies. More detail on inventory development can be found in the 'AusAgLCI Methodology for developing Life Cycle Inventory' documents located at www.auslci.alcas.asn.au. Using pumping energy formula Power=pgQh/1000n where p is density of the liquid, g is gravitation constant, Q is discharge, H is head pumped, n is efficiency of pump and motor. The infractructure is based on typical assumption in flygt EPD. Functional flow is 1m3 of liquid. Geography: Refers to an average production in Australia. Technology: Average Time period: Data collected for 2012 Version: 1.0 Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU

Sector
Processing
Contributor
—
Last updated
30 Aug 2012
Reference ID
76e8b770-0d6b-3068-93ff-76b9622732c2

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Pumping, irrigation, 10m pumping depth, 50% electricity, NSW {AU}| | AusLCI, U
Sampling procedure
—
Creation date
30 Aug 2012
Is copyright protected
No
Is infrastructure process
No
Tags
processing
Sources
—

Product outputs

Flow AmountUnitComment
Pumping, irrigation, 10m pumping depth, 50% electricity, NSW {AU}| | AusLCI, U 1.0 m3 —

Technical inputs

Flow AmountUnitComment
Diesel, burned in building machine {GLO}| market for diesel, burned in building machine | Cut-off, U 0.16498316498316495 MJ —
Diesel, burned in building machine {GLO}| market for diesel, burned in building machine | Cut-off, U 0.0 MJ —
Electricity, low voltage {AU-NSW}| market for electricity, low voltage | AusLCI, U 0.025778619528619526 kWh —
Water pump, irrigation, 25kg {AU}| | AusLCI, U 0.000015017757483510909 Item(s) water pump in ratios to mass of pump specified and divided by total volume of water pumped over life.

Parameters

NameValueFormulaDescription
Power_Elec_KWh 0.025778619528619526 Fraction_electric*(9.8*D_liquid*Head_m/(Elec_Motor_Eff*Pump_Eff))/3600 Electrical energy required
Head_m 10.0 — Head being pumped against. Combination of lift and backpressure
Pump_Eff 0.66 — Efficiency of pump at moving water. Default is 66% or 0.66
Duty_of_Pump 197100.0 Pump_Life_years*Hours_use_peryear*Flowrate —
Pump_Life_years 15.0 — life of pump, used for infrastructure
Power_Diesel_MJ 0.16498316498316495 (1-Fraction_electric)*3.6*(9.8*D_liquid*Head_m/(Diesel_Motor_Eff*Pump_Eff))/3600 Diesel energy required
D_liquid 1.0 — kg/l density of liquid being pumps for water assume 1
Mass_of_pump 74.0 — Total mass of pump and motor in kg - used for infrastructure calculation
Hours_use_peryear 3650.0 — Hours of use per year - used for infrastructure
Diesel_Motor_Eff 0.45 — Efficiency of motor energy delivery to pump, default for electricity is 0.45 or 45%^ Diesel Engine. Freedom CAR & Vehicle Technologies Program. U.S. Department of Energy, Aug. 2003. Web.
Fraction_low_pop — — Fraction of pumping happening in low population areas
Flowrate 3.6 — m3 per hour, used for infrastructure
Elec_Motor_Eff 0.8 — Efficiency of motor energy delivery to pump, default for electricity is 0.8 or 80%
Fraction_electric 0.5 — Fraction of energy delivered by electric motors. Alternative is diesel motor