Electricity, natural gas, CC, NT, at power plant {AU}| | AusLCI, U

Unit process Australia v00.00.000

Included processes:Includes the production of fuels and generation of electricitys well is capital equipment for power plant construction. Remark: Natural gas combined cycle based power generation in Nothern Territory - effiency indicated by ESAA 2012 is 40% Geography: Refers to an average production in the Australia. Technology: Average Time period: Data collected for 2012 Version: 1.0 Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU

Sector
Energy
Contributor
—
Last updated
07 Apr 2013
Reference ID
7985db71-24e2-3375-b6e2-06396dc8552d

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Electricity, natural gas, CC, NT, at power plant {AU}| | AusLCI, U
Sampling procedure
Data were collected from national reporting on electricity production and fuel use and from emission estimation values in the national pollutant inventory guidebooks.
Creation date
07 Apr 2013
Is copyright protected
No
Is infrastructure process
No
Tags
energy
Sources
Energy Gas Australia 2018/2018/Australian Energy Council.
Australian National Greenhouse Accounts/2012/DCCEE
Water and the electricity generation industry/2009/Smart and Aspinall

Product outputs

Flow AmountUnitComment
Electricity, natural gas, CC, NT, at power plant {AU}| | AusLCI, U 1.0 MWh —

Technical inputs

Flow AmountUnitComment
Electricity, natural gas, CC, NT, at power plant {AU}| | AusLCI, U 0.016 MWh —
Gas power plant, 300MW electrical {GLO}| market for gas power plant, 300MW electrical | Cut-off, U 0.0000000459 Item(s) —
Natural gas, high pressure, Northern Territory {AU}| | AusLCI, U 0.1594896331738437 t —
Tap water, at user, Australia {AU}| | AusLCI, U 1590.0 kg Water may be self extracted but likely to need some treatment so local water supply process is used

Outputs to treatment

Flow AmountUnitComment
Wastewater treatment {AU}| | AusLCI, U 0.8149362041467305 m3 —

Elementary flow inputs

Flow Sub-compartment AmountUnitComment
Oxygen in air 0.30125199352 t —

Elementary flow outputs

Flow CompartmentSub-compartment AmountUnitComment
Arsenic, ion Emissions to air— 0.000767128 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 11 data points.
Benzene Emissions to air— 0.060355923 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 2 data points.
Benzene, ethyl- Emissions to air— 0.159988693 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 2 data points.
Beryllium (II) Emissions to air— 0.0000452 g From NPI (2011) data for all AU natural gas (turbine) power plants. Uncertainty based on variation in different results report in NPI based on 8 data points.
Cadmium (II) Emissions to air— 0.002313498 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 9 data points.
Carbon dioxide, fossil Emission to airunspecified 413.28 kg From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
Carbon monoxide Emissions to air— 1277.2 g From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
Chromium (VI) Emissions to air— 0.00027473 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 8 data points.
Chromium, ion Emissions to air— 0.002895569 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 9 data points.
Copper, ion Emissions to air— 0.002037096 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 9 data points.
Cumene Emissions to air— 0.001497075 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on generic estimate as only 1 value reported in NPI
Dinitrogen monoxide Emissions to air— 0.776 g From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
Electricity, delivered to user Non material emissions— 1.0 MWh Indicator used to track energy end use through the database
Fluoride Emissions to air— 0.034402767 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 6 data points.
Lead (II) Emissions to air— 0.001532611 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 9 data points.
Magnesium oxide Emissions to air— 0.000380102 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 5 data points.
Mercury (II) Emissions to air— 0.000600716 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 9 data points.
Methane Emissions to air— 36.08 g From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
NMVOC, non-methane volatile organic compounds Emissions to air— 15.68 g From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
Nickel (II) Emissions to air— 0.0033913 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 9 data points.
Nitrogen oxides Emissions to air— 195.84 g From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
PAH, polycyclic aromatic hydrocarbons Emissions to air— 0.054739968 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 10 data points.
Particulates, < 10 um Emissions to air— 30.56591502 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 10 data points.
Particulates, < 2.5 um Emissions to air— 12.78558143 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 6 data points.
Polychlorinated dioxins and furans Emissions to air— 0.000000056 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 6 data points.
Powerplant conversion losses Non material emissions— 1.2222222222222223 MWh Indicator used to track energy end use through the database
Sulfur oxides Emissions to air— 186.32 g From NIR (2009) data, Table 3.7, for all major SA brown coal power plants.
Sulfuric acid Emissions to air— 0.0000000138 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 2 data points.
Toluene Emissions to air— 0.64968747 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 2 data points.
Water Emissions to air— 0.8149362041467305 t Evapouration - calculated by difference.
Xylene Emissions to air— 0.319644665 g From NPI (2011) data for all AU natural gas (combined cycle) power plants. Uncertainty based on variation in different results report in NPI based on 2 data points.
Xylene Emissions to air— 0.116154658 g From NPI (2011) data for all AU natural gas (turbine) power plants. Uncertainty based on variation in different results report in NPI based on 10 data points.

Parameters

NameValueFormulaDescription
EF_SO2 23.29 — (2,1,1,1,1,na), [g/GJ] average emission of SO2 from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
m_gasperMWh 0.1594896331738437 GJ_FuelperMWH/ED_NaturalGas Tonnes/MWh
EF_N2O 0.097 — (2,1,1,1,1,na), [g/GJ] average emission of N2O from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
NGAF_Adjust 12.0 — Factor used to adjust efficiency to get NSW grid to meet National Greenhouse Accounts factors
EF_CH4 4.51 — (2,1,1,1,1,na), [g/GJ] average emission of CH4 from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
H_in_Gas 0.25 — (4,3,2,1,1,2) Typical hydrogen content in Natural gas
houseload 0.016 — Percentage of electricity generated that is self-consumed at generation plant. Derived to match energy sent out vs energy generated from Table 2.4, 2.5 and 2.6, Australian Energy Council, Electricity Gas Australia Highlights FY 2022-23.
ED_NaturalGas 50.16 — MJ/kg Natural gas
O2forCO2 0.727 — Ratio of Oxygen required to oxidise carbon to carbon dioxide
O2forNO2 0.348 — Ratio of Oxygen required to oxidise Nitrogen to nitrogen dioxide (NO2) used as proxy for NOx
GWh_GEN 25668.0 — (1,1,1,1,1,na), [GWh] Total electricity generated using Natural Gas in Australia in 2010 - ESAA 2011 table 2.6
Water 1.59 — (1,2,1,1,1,na) [kL/MWh], average data from Smart & Aspinall 2009, Table 9 to 13 and Table 32
EF_NMVOC 1.96 — (2,1,1,1,1,na), [g/GJ] average emission of NMVOC from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
O2forCO 0.571 — Ratio of Oxygen required to oxidise carbon to carbon monoxide
Gen_eff 0.45 — (2,1,1,1,1,na) Generation effiecncy based on electricity generated. Derived from Table 2.9 ESAA 2012 after accounting for other thermal technology effciencies
GJ_FuelperMWH 8.0 3.6/Gen_eff GJ/MWH
WaterTotal 1.629872408293461 Water+H_in_Gas*m_gasperMWh M3 water/MWh
EF_CO 159.65 — (2,1,1,1,1,na), [g/GJ] average emission of CO from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
EF_NOx 24.48 — (2,1,1,1,1,na), [g/GJ] average emission of NOx from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
EF_CO2 51.66 — (2,1,1,1,1,na), [kg/GJ] average emission of CO2 from main fuel, NGGI 2009 data, Table 3.7, for all major natural gas power plants.
Water_to_WWT 0.5 — (5,5,5,5,1,5) Fraction of total water to Waste Water Treatment
O2_req 301.25199352 (GJ_FuelperMWH*EF_CO2*O2forCO2)+(((GJ_FuelperMWH*EF_CO*O2forCO)+(GJ_FuelperMWH*EF_NOx*O2forNO2))/1000) kg Oxygen required total