Electricity, high voltage {AU}| electricity from coal, high voltage | AusLCI, U
Unit process Australia v00.00.000
Included processes: production and transmission of electricity from Black Brown coal sources in Australia Remark: This process is used for consequential analysis when coal base load supply is required Geography: Refers to an average production in the Australia. Technology: Average Time period: Data collected for 2012 Version: 1.0 Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU
- Sector
- Energy
- Contributor
- —
- Last updated
- 07 Apr 2013
- Reference ID
9b7dbd36-33d2-3e03-8600-acc107af18e5
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity, high voltage {AU}| electricity from coal, high voltage | AusLCI, U
- Sampling procedure
- —
- Creation date
- 07 Apr 2013
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
- —
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, high voltage {AU}| electricity from coal, high voltage | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at powerplant {AU}| electricity from coal | AusLCI, U | 1.053740779768177 | kWh | — |
| Transmission network, electricity, high voltage {GLO}| market for transmission network, electricity, high voltage | Cut-off, U | 0.00000000844 | km | approximation with Swiss data |
| Transmission network, long-distance {GLO}| market for transmission network, long-distance | Cut-off, U | 0.000000000317 | km | approximation with data from Europe |
Elementary flow inputs
| Flow | Sub-compartment | Amount | Unit | Comment |
|---|---|---|---|---|
| Occupation, urban, green areas | — | 0.039761431411530816 | m2*a | — |
Elementary flow outputs
| Flow | Compartment | Sub-compartment | Amount | Unit | Comment |
|---|---|---|---|---|---|
| Dinitrogen monoxide | Emission to air | low population density | 0.000005 | kg | approximation with Swiss data |
| Ozone | Emission to air | low population density | 0.0000045 | kg | approximation with Swiss data |
| Powerplant conversion losses | Non material emissions | — | 0.05374077976817704 | kWh | — |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| Width | 20.0 | — | (5,5,5,5,na,na)[m] Estimated Width occupied by the power line NOT CHANGED |
| TL_Total_Aus | 458000000.0 | — | (1,1,1,1,1,na)[m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia NOT CHANGED |
| Occupation_m2a | 0.039761431411530816 | (TL_Total_Aus*Width)/E_Total_Aus/1000000 | [m2a] Average area occupied for transmission per GWh/100000 to get to kWhs |
| E_Total_Aus | 230374.0 | — | (1,1,1,1,1,na)[GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5 |
| Tranmission_Loss | 0.051 | — | (1,1,1,1,1,na)[-] Rate of loss from transmission |