Electricity, high voltage {AU}| electricity from coal, high voltage | AusLCI, U

Unit process Australia v00.00.000

Included processes: production and transmission of electricity from Black Brown coal sources in Australia Remark: This process is used for consequential analysis when coal base load supply is required Geography: Refers to an average production in the Australia. Technology: Average Time period: Data collected for 2012 Version: 1.0 Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU

Sector
Energy
Contributor
—
Last updated
07 Apr 2013
Reference ID
9b7dbd36-33d2-3e03-8600-acc107af18e5

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Electricity, high voltage {AU}| electricity from coal, high voltage | AusLCI, U
Sampling procedure
—
Creation date
07 Apr 2013
Is copyright protected
No
Is infrastructure process
No
Tags
energy
Sources
—

Product outputs

Flow AmountUnitComment
Electricity, high voltage {AU}| electricity from coal, high voltage | AusLCI, U 1.0 kWh —

Technical inputs

Flow AmountUnitComment
Electricity, at powerplant {AU}| electricity from coal | AusLCI, U 1.053740779768177 kWh —
Transmission network, electricity, high voltage {GLO}| market for transmission network, electricity, high voltage | Cut-off, U 0.00000000844 km approximation with Swiss data
Transmission network, long-distance {GLO}| market for transmission network, long-distance | Cut-off, U 0.000000000317 km approximation with data from Europe

Elementary flow inputs

Flow Sub-compartment AmountUnitComment
Occupation, urban, green areas — 0.039761431411530816 m2*a —

Elementary flow outputs

Flow CompartmentSub-compartment AmountUnitComment
Dinitrogen monoxide Emission to airlow population density 0.000005 kg approximation with Swiss data
Ozone Emission to airlow population density 0.0000045 kg approximation with Swiss data
Powerplant conversion losses Non material emissions— 0.05374077976817704 kWh —

Parameters

NameValueFormulaDescription
Width 20.0 — (5,5,5,5,na,na)[m] Estimated Width occupied by the power line NOT CHANGED
TL_Total_Aus 458000000.0 — (1,1,1,1,1,na)[m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia NOT CHANGED
Occupation_m2a 0.039761431411530816 (TL_Total_Aus*Width)/E_Total_Aus/1000000 [m2a] Average area occupied for transmission per GWh/100000 to get to kWhs
E_Total_Aus 230374.0 — (1,1,1,1,1,na)[GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5
Tranmission_Loss 0.051 — (1,1,1,1,1,na)[-] Rate of loss from transmission