Electricity, low voltage {AU-NT}| market for residual electricity mix, low voltage | AusLCI, U
Unit process v00.00.000
Remark: Distribution of electricity including distribution losses. GeographyNorthen Territory, Australia. Technology: Current Version: 1.0 Included processes start:Process begins withthe delivery of high voltage power into the distribution network Inlcuded processes end: Process ends with the delivery of low voltage <= 415 V Excluded processes:Heat emissions not included. Start date:2011-07-0 End date:2102-06-30 is data valid for entire period: false Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Generator/publicator: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU
- Sector
- Energy
- Contributor
- —
- Last updated
- 07 Apr 2013
- Reference ID
9d53eca3-443f-3603-8a92-8c3e0380d049
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity, low voltage {AU-NT}| market for residual electricity mix, low voltage | AusLCI, U
- Sampling procedure
- Sulfur hexafluoride and distribution infracstructure taken from ecoinvent.
- Creation date
- 07 Apr 2013
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Energy Gas Australia 2018/2018/Australian Energy Council.
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, low voltage {AU-NT}| market for residual electricity mix, low voltage | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Distribution network, electricity, low voltage {GLO}| market for distribution network, electricity, low voltage | Cut-off, U | 0.000000294 | km | (3,1,4,5,3,5); based on consumption statistics |
| Electricity, high voltage {AU-NT}| residual electricity mix, high voltage | AusLCI, U | 1.0606703436571914 | kWh | High voltage input including distribution loss. |
| Sulfur hexafluoride, liquid {RoW}| market for sulfur hexafluoride, liquid | Cut-off, U | 0.00000000459 | kg | (1,1,2,5,1,3); assumed with data of German statistics |
Elementary flow outputs
| Flow | Compartment | Sub-compartment | Amount | Unit | Comment |
|---|---|---|---|---|---|
| Energy losses in electricty distribution | Non material emissions | — | 0.06067034365719137 | kWh | — |
| Sulfur hexafluoride | Emission to air | unspecified | 0.00000000459 | kg | (1,1,2,5,1,3); assumed with data of German statistics |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| Distribution_loss | 0.0572 | — | State specific low voltage distribution loss factor derived from AEMO FY21-22 data |