Electricity, at powerplant {AU-VIC}| residual electricity production mix | AusLCI, U

Unit process v00.00.000

Remark: Production mix for region.. Geography: Victoria Technology: Current Version: Start date: 2022-08-19 End date: 2022-10-10

Sector
Energy
Contributor
—
Last updated
10 Oct 2022
Reference ID
a7b33027-c6d0-3e10-9a89-faab6a4e1765

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Electricity, at powerplant {AU-VIC}| residual electricity production mix | AusLCI, U
Sampling procedure
—
Creation date
10 Oct 2022
Is copyright protected
No
Is infrastructure process
No
Tags
energy
Sources
Australian Energy Update 2024
Electricity Gas Australia Highlights FY 2022-23

Product outputs

Flow AmountUnitComment
Electricity, at powerplant {AU-VIC}| residual electricity production mix | AusLCI, U 1.0 kWh —

Technical inputs

Flow AmountUnitComment
Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U 0.0 kWh —
Electricity, at powerplant {AU-TAS}| residual electricity production mix | AusLCI, U 0.0 kWh —
Electricity, brown coal Vic, at power plant {AU}| | AusLCI, U 0.6737289388896979 kWh —
Electricity, high voltage {AU}| electricity production, wind, >3MW turbine, onshore | Cut-off, U 0.15342517281626905 kWh —
Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U 0.001504244474481223 kWh —
Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U 0.005448123892591612 kWh —
Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U 0.0 kWh —
Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U 0.0004717612216674727 kWh —
Electricity, high voltage {RoW}| electricity production, hydro, reservoir, non-alpine region | Cut-off, U 0.06251187398735081 kWh —
Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U 0.05159885384532866 kWh —
Electricity, low voltage {AU}| electricity production, photovoltaic, 570kWp open ground installation, multi-Si | Cut-off, U 0.029196295223639254 kWh —
Electricity, natural gas, GT, at power plant {AU}| | AusLCI, U 0.013500861952276148 kWh —
Electricity, natural gas, steam, at power plant {AU}| | AusLCI, U 0.009096669644493214 kWh —

Parameters

NameValueFormulaDescription
I_Re 1.0 1-ExcludeRenewables —
VSREC_Wind 2815.444 — Renewable Energy Certificates (RECs) from wind electricity generation that may be voluntarily surrendered using an average of CY22&23 data
E_SGas 70.477 — [GWh] Total production of electricity from E_SGas Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
E_Solar_Sc 2447.98573 — [GWh] Total production of electricity from Small-Scale Solar Generation derived from Table O Australian Energy Statistics FY22-23. The reported GWh reflects the proportion of small-scale solar generation which is sent to grid according to NGA 2023.
NGAF_adjust — — This factor is used to adjust the electricty mix to meet NGA factors value for 2023.
ExcludeRenewables — — Switch to exclude renewables from the electricity mix. Set parameter to "1" to exclude renewables from this inventory mix. By defaults should be set to "0" to include renewables in the the grid mix.
E_Hydro 2969.91405 E_Hydro_Actual —
E_HeatPump 990.7 — [GWh] Total production of electricity from E_HeatPump Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
E_Wind 10003.73426 E_Wind_Actual+NGAF_adjust —
ExcludeNonRenewables — — Switch to exclude non-renewables from the electricity mix. Set parameter to "1" to exclude renewables from this inventory mix. By defaults should be set to "0" to include non-renewables in the the grid mix.
E_Hydro_Actual 2969.91405 — [GWh] Total production of electricity from E_Hydro Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 4
E_Wind_Actual 10003.73426 — [GWh] Total production of electricity from E_Wind Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 5
VSREC_Hydro 41.102 — Renewable Energy Certificates (RECs) from hydro electricity generation that may be voluntarily surrendered using an average of CY22&23 data
VSREC_Biogas 29.681 — Renewable Energy Certificates (RECs) from biogas electricity generation that may be voluntarily surrendered using an average of CY22&23 data
NRE_Total_Vic 32624.3516217 E_BlackCoal+E_BrownCoal+E_Oil+E_GSteam+E_GTurbine [GWh] Total production of electricity from non-renewable energy in Victoria in FY 2022-23
E_Lgas 284.937 — [GWh] Total production of electricity from E_Lgas Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
VSREC_Total 4497.057 VSREC_Wind+VSREC_Hydro+VSREC_SolarSC+VSREC_SolarLC+VSREC_Biomass+VSREC_Biogas+VSREC_HeatPump [GWh] Total Renewable Energy Certificates (RECs) voluntarily surrendered 2023
E_GSteam 426.198 — [GWh] Total production of electricity from E_GSteam Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 8
E_BLiquor — — [GWh] Total production of electricity from E_BLiquor Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
E_Res_Total_Vic 46852.0916617 E_Total_VIC-VSREC_Total [GWh] Total production of electricity excluding renewables traded through generation certificates FY 2022-23
E_Solar_Lc 1957.049 — [GWh] Total production of electricity from Large-Scale Solar Generation derived from Table O Australian Energy Statistics FY22-23
VSREC_SolarSC 30.4715 — Renewable Energy Certificates (RECs) from small-scale solar electricity generation that may be voluntarily surrendered using an average of CY22&23 data
E_BlackCoal — — [GWh] Total production of electricity from E_BlackCoal Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 5
E_Solar 4405.034729999999 E_Solar_Lc+ E_Solar_Sc —
VSREC_SolarLC 589.1415 — Renewable Energy Certificates (RECs) from large-scale solar electricity generation that may be voluntarily surrendered using an average of CY22&23 data
E_BrownCoal 31565.61 E_BrownCoal_Actual-NGAF_adjust —
E_Biomass 22.62 — [GWh] Total production of electricity from E_Biomass Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
Import_Fr_Tas — — Net Import (GWh) VIC from TAS. Import and export of energy refers to interstate trading. Import and export of energy refers to interstate trading.
E_BrownCoal_Actual 31565.61 — [GWh] Total production of electricity from E_BrownCoal Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 6
E_GTurbine 632.5436217 — [GWh] Total production of electricity from E_GTurbine Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 9
I_NRe 1.0 1-ExcludeNonRenewables —
E_Total_Vic 51349.1486617 RE_Total_Vic*I_Re+NRE_Total_Vic*I_Nre+Import_Fr_TAS [GWh] Total production of electricity in Victoria in FY 2022-23
RE_Total_Vic 18724.797039999998 E_Hydro+E_heatpump+E_BLiquor+E_Lgas+E_SGas+E_Wind+E_solar [GWh] Total production of electricity from renewable energy in Victoria in FY 2022-23
E_Oil — — [GWh] Total production of electricity from E_Oil Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 7
VSREC_Biomass 0.517 — Renewable Energy Certificates (RECs) from biomass electricity generation that may be voluntarily surrendered using an average of CY22&23 data
VSREC_HeatPump 990.7 E_Heatpump Assume heat pump generation is ‘behind the meter’ and 100% voluntarily surrendered