Pumping, irrigation, 40m total pumping head, 100% electricity {AU}| | AusLCI, U

Unit process Australia v00.00.000

Included processes: Include infrastructure, fuel production and use of pump for irrigation. Remark:This inventory has been developed as part of the AusAgLCI initiative funded by a partnership of Australian Research and Development Corporations (RIRDC, CRDC, GRDC, SRDC, HAL, MLA, DA, FWPA) and Research Agencies (CSIRO, USQ and Q DAFF), with technical support from Life Cycle Strategies. More detail on inventory development can be found in the 'AusAgLCI Methodology for developing Life Cycle Inventory' documents located at www.auslci.alcas.asn.au. Using pumping energy formulae Power=pgQh/1000n wher p is density of the liquid, g is gravitation constant, Q is discharge, H is head pumped, n is efficiency of pump and motor. The infractructure is based on typical assumption in flygt EPD. Functional flow is 1m3 of liquid. Geography: Refers to an average production in the Australia. Technology: Average Time period: Data collected for 2012 Version: 1.0 Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU

Sector
Processing
Contributor
—
Last updated
30 Aug 2012
Reference ID
b0b2f0cf-80a2-3160-9426-0dbd48f98d87

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Pumping, irrigation, 40m total pumping head, 100% electricity {AU}| | AusLCI, U
Sampling procedure
—
Creation date
30 Aug 2012
Is copyright protected
No
Is infrastructure process
No
Tags
processing
Sources
—

Product outputs

Flow AmountUnitComment
Pumping, irrigation, 40m total pumping head, 100% electricity {AU}| | AusLCI, U 1.0 m3 —

Technical inputs

Flow AmountUnitComment
Diesel, burned in building machine {GLO}| market for diesel, burned in building machine | Cut-off, U 0.0 MJ —
Electricity, low voltage {AU}| market for electricity, low voltage | AusLCI, U 0.2062289562289562 kWh —
Water pump, irrigation, 25kg {AU}| | AusLCI, U 0.000015017757483510909 Item(s) water pump in ratios to mass of pump specified and divided by total volume of water pumped over life.

Parameters

NameValueFormulaDescription
Hours_use_peryear 3650.0 — Hours of use per year - used for infrastructure
Elec_Motor_Eff 0.8 — Efficiency of motor energy delivery to pump, default for electricity is 0.8 or 80%
Fraction_electric 1.0 — Fraction of energy delivered by electric motors. Alternative is diesel motor
Pump_Life_years 15.0 — life of pump, used for infrastructure
Flowrate 3.6 — m3 per hour, used for infrastructure
Pump_Eff 0.66 — Efficiency of pump at moving water. Default is 66% or 0.66
Power_Diesel_MJ — (1-Fraction_electric)*3.6*(9.8*D_liquid*Head_m/(Diesel_Motor_Eff*Pump_Eff))/3600 Diesel energy required
Diesel_Motor_Eff 0.45 — Efficiency of motor energy delivery to pump, default for electricity is 0.45 or 45%^ Diesel Engine. Freedom CAR & Vehicle Technologies Program. U.S. Department of Energy, Aug. 2003. Web.
Mass_of_pump 74.0 — Total mass of pump and motor in kg - used for infrastructure calculation
Power_Elec_KWh 0.2062289562289562 Fraction_electric*(9.8*D_liquid*Head_m/(Elec_Motor_Eff*Pump_Eff))/3600 Electrical energy required
Fraction_low_pop — — Fraction of pumping happening in low population areas
Duty_of_Pump 197100.0 Pump_Life_years*Hours_use_peryear*Flowrate —
Head_m 40.0 — Head being pumped against. Combination of lift and backpressure
D_liquid 1.0 — kg/l density of liquid being pumps for water assume 1