Electricity, at powerplant {AU-TAS}| residual electricity production mix | AusLCI, U
Unit process v00.00.000
Remark: Production mix for region.. Geography: Tasmania Technology: Current Start date: 2022-08-19 End date: 2022-10-10
- Sector
- Energy
- Contributor
- —
- Last updated
- 10 Oct 2022
- Reference ID
dfe968b4-e4c6-3885-95b5-b3354f0e053a
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity, at powerplant {AU-TAS}| residual electricity production mix | AusLCI, U
- Sampling procedure
- —
- Creation date
- 10 Oct 2022
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Australian Energy Update 2024
Electricity Gas Australia Highlights FY 2022-23
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at powerplant {AU-TAS}| residual electricity production mix | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U | 0.0 | kWh | — |
| Electricity, at powerplant {AU-VIC}| residual electricity production mix | AusLCI, U | 0.08410723203594803 | kWh | — |
| Electricity, high voltage {AU}| electricity production, wind, >3MW turbine, onshore | Cut-off, U | 0.14637465192873503 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.0025989466304994786 | kWh | — |
| Electricity, high voltage {RoW}| electricity production, hydro, reservoir, non-alpine region | Cut-off, U | 0.7464607683200195 | kWh | — |
| Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U | 0.014135091469085153 | kWh | — |
| Electricity, low voltage {AU}| electricity production, photovoltaic, 570kWp open ground installation, multi-Si | Cut-off, U | 0.00015581291267285964 | kWh | — |
| Electricity, natural gas, CC, TAS, at power plant {AU}| | AusLCI, U | 0.0 | kWh | — |
| Electricity, natural gas, GT, at power plant {AU}| | AusLCI, U | 0.006167496703040078 | kWh | — |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| E_Solar_Sc | 157.84725 | — | [GWh] Total production of electricity from Small-Scale Solar Generation derived from Table O Australian Energy Statistics FY22-23. The reported GWh reflects the proportion of small-scale solar generation which is sent to grid according to NGA 2023. |
| VSREC_SolarSC | 2.6735 | — | Renewable Energy Certificates (RECs) from small-scale solar electricity generation that may be voluntarily surrendered using an average of CY22&23 data |
| VSREC_Total | 281.096 | VSREC_Wind+VSREC_Hydro+VSREC_SolarSC+VSREC_SolarLC+VSREC_Biomass+VSREC_Biogas+VSREC_HeatPump | [GWh] Total Renewable Energy Certificates (RECs) voluntarily surrendered 2023 |
| VSREC_SolarLC | 2.0025 | — | Renewable Energy Certificates (RECs) from large-scale solar electricity generation that may be voluntarily surrendered using an average of CY22&23 data |
| E_Hydro_Actual | 8308.2 | — | [GWh] Total production of electricity from Hydro Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 2 |
| E_Wind | 1730.263131 | — | [GWh] Total production of electricity from Wind Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 2 |
| E_GCombined | — | — | [GWh] Total production of electricity from GCombined Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 4 |
| NRE_Total_Tas | 67.7062185 | E_GTurbine+E_Gcombined | [GWh] Total production of electricity from non-renewable energy in Tasmania in FY 2022-23 |
| E_Solar_Lc | 3.713 | — | [GWh] Total production of electricity from Large-Scale Solar Generation derived from Table O Australian Energy Statistics FY22-23 |
| I_NRe | 1.0 | 1-ExcludeNonRenewables | — |
| E_HeatPump | 34.219 | — | [GWh] Total production of electricity from HeatPump Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11) |
| VSREC_Wind | 123.3755 | — | Renewable Energy Certificates (RECs) from wind electricity generation that may be voluntarily surrendered using an average of CY22&23 data |
| VSREC_Biomass | — | — | Renewable Energy Certificates (RECs) from biomass electricity generation that may be voluntarily surrendered using an average of CY22&23 data |
| Import_Fr_VIC | 923.3215523 | — | Net Import (GWh) TAS from VIC. Import and export of energy refers to interstate trading. Import and export of energy refers to interstate trading. |
| E_GTurbine | 67.7062185 | E_GTurbine_Actual-NGAF_Adjust | — |
| VSREC_Biogas | 5.204 | — | Renewable Energy Certificates (RECs) from biogas electricity generation that may be voluntarily surrendered using an average of CY22&23 data |
| E_Res_Total_Tas | 10977.9091518 | E_Total_Tas-VSREC_Total | [GWh] Total production of electricity excluding renewables traded through generation certificates FY 2022-23 |
| NGAF_Adjust | — | — | This factor is used to adjust the electricty mix to meet NGA factors value for 2023. |
| E_Total_Tas | 11259.0051518 | RE_Total_Tas*I_Re+NRE_Total_Tas*I_Nre+Import_Fr_VIC | [GWh] Total production of electricity Tasmania in FY 2022-23 |
| E_Lgas | 33.735 | — | [GWh] Total production of electricity from Lgas Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11) |
| I_Re | 1.0 | 1-ExcludeRenewables | — |
| ExcludeRenewables | — | — | Switch to exclude renewables from the electricity mix. Set parameter to "1" to exclude renewables from this inventory mix. By defaults should be set to "0" to include renewables in the the grid mix. |
| ExcludeNonRenewables | — | — | Switch to exclude non-renewables from the electricity mix. Set parameter to "1" to exclude renewables from this inventory mix. By defaults should be set to "0" to include non-renewables in the the grid mix. |
| VSREC_Hydro | 113.6215 | — | Renewable Energy Certificates (RECs) from hydro electricity generation that may be voluntarily surrendered using an average of CY22&23 data |
| E_GTurbine_Actual | 67.7062185 | — | [GWh] Total production of electricity from GTurbine Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 3 |
| VSREC_HeatPump | 34.219 | E_Heatpump | Assume heat pump generation is ‘behind the meter’ and 100% voluntarily surrendered |
| E_Solar | 161.56025 | E_Solar_Lc+ E_Solar_Sc | E_Solar |
| RE_Total_Tas | 10267.977381 | E_Hydro+E_heatpump+E_Lgas+E_Wind+E_solar | [GWh] Total production of electricity from renewable energy in Tasmania in FY 2022-23 |
| E_Hydro | 8308.2 | E_Hydro_Actual+NGAF_Adjust | — |