Electricity mix, 2050 Northern Territory {AU}|_Obsolete | | AusLCI, U
Unit process Australia v00.00.000
NT electricity mix data was inputted into Excel. Scaling Renewable sources identified, Solar, Heat Pump, and Lgas. Gap identified at 2050 by sum of all non-renewable energy sources. Scaling renewable percentage was multiplied by 2050 gap to find the 2050 value for each scaling renewable. Using a linear excel function, years 2021 to 2050 were calculated and the 2050 values were held constant for 2050 to 2080. Functions in excel were used for non-renewable sources to decrease to 0 by 2050. The average for each energy source was determined for 2050 and 2080 and are the values used in parameters within the electricity mix 2050 NT and electricity mix 2080 NT processes.
- Sector
- Energy
- Contributor
- —
- Last updated
- 30 Dec 1899
- Reference ID
e02713e5-55c8-3a6a-9368-fd12e4b8fef4
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity mix, 2050 Northern Territory {AU}|_Obsolete | | AusLCI, U
- Sampling procedure
- —
- Creation date
- 30 Dec 1899
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Energy Gas Australia 2018/2018/Australian Energy Council.
Energy in Australia 2011/2011/ABARE
State of the energy market 2009/2009/Australian Energy Regulator
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity mix, 2050 Northern Territory {AU}|_Obsolete | | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U | 0.026732200167572582 | kWh | — |
| Electricity, high voltage {AU}| electricity production, oil | Cut-off, U | 0.019814242909848668 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.03653572049342526 | kWh | — |
| Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U | 0.46431775364030403 | kWh | — |
| Electricity, natural gas, CC, NT, at power plant {AU}| | AusLCI, U | 0.13618096491398082 | kWh | — |
| Electricity, natural gas, GT, NT, at power plant {AU}| | AusLCI, U | 0.31641911787486854 | kWh | — |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| E_Oil | 36.85746964 | — | [GWh] Total production of electricity from Oil products in NT in 2017. EGA Australia 2018 Table 2.6 equates to 1.7% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Total_NT | 1860.1502872300002 | RE_Total_NT+NRE_Total_NT | [GWh] Total production of electricity in Northern Territory in 2010 |
| E_HeatPump | 49.72590982 | — | [GWh] Total production of electricity from Heat pump in NT in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.3% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value. |
| E_GTurbine | 588.587113 | — | [GWh] Total production of electricity from Gas turbine in NT in 2017. EGA Australia 2018 Table 2.5 equates to 58.7% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Total_Aus | 230374.0 | — | [GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5 |
| RE_Total_NT | 981.38864359 | E_heatpump+E_Lgas+E_solar | [GWh] Total production of electricity from renewable energy in Northern Territory in 2010 |
| E_GCombined | 253.317061 | — | [GWh] Total production of electricity from Combined cycle in NT in 2017. EGA Australia 2018 Table 2.5 equates to 38% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| TL_Total_Aus | 458000000.0 | — | [m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia |
| E_Lgas | 67.96193097 | — | [GWh] Total production of electricity from Landfill gas in NT in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.5% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value. |
| E_Solar | 863.7008028 | — | [GWh] Total production of electricity from Solar in NT in 2017. Department of the Environment and Energy, Australian Energy Statistics, Table O, August 2018, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value. |
| NRE_Total_NT | 878.7616436400001 | E_Oil+E_GCombined+E_GTurbine | [GWh] Total production of electricity from non-renewable energy in Northern Territory in 2010 |