Electricity mix, 2050 Northern Territory {AU}|_Obsolete | | AusLCI, U

Unit process Australia v00.00.000

NT electricity mix data was inputted into Excel. Scaling Renewable sources identified, Solar, Heat Pump, and Lgas. Gap identified at 2050 by sum of all non-renewable energy sources. Scaling renewable percentage was multiplied by 2050 gap to find the 2050 value for each scaling renewable. Using a linear excel function, years 2021 to 2050 were calculated and the 2050 values were held constant for 2050 to 2080. Functions in excel were used for non-renewable sources to decrease to 0 by 2050. The average for each energy source was determined for 2050 and 2080 and are the values used in parameters within the electricity mix 2050 NT and electricity mix 2080 NT processes.

Sector
Energy
Contributor
—
Last updated
30 Dec 1899
Reference ID
e02713e5-55c8-3a6a-9368-fd12e4b8fef4

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Electricity mix, 2050 Northern Territory {AU}|_Obsolete | | AusLCI, U
Sampling procedure
—
Creation date
30 Dec 1899
Is copyright protected
No
Is infrastructure process
No
Tags
energy
Sources
Energy Gas Australia 2018/2018/Australian Energy Council.
Energy in Australia 2011/2011/ABARE
State of the energy market 2009/2009/Australian Energy Regulator

Product outputs

Flow AmountUnitComment
Electricity mix, 2050 Northern Territory {AU}|_Obsolete | | AusLCI, U 1.0 kWh —

Technical inputs

Flow AmountUnitComment
Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U 0.026732200167572582 kWh —
Electricity, high voltage {AU}| electricity production, oil | Cut-off, U 0.019814242909848668 kWh —
Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U 0.03653572049342526 kWh —
Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U 0.46431775364030403 kWh —
Electricity, natural gas, CC, NT, at power plant {AU}| | AusLCI, U 0.13618096491398082 kWh —
Electricity, natural gas, GT, NT, at power plant {AU}| | AusLCI, U 0.31641911787486854 kWh —

Parameters

NameValueFormulaDescription
E_Oil 36.85746964 — [GWh] Total production of electricity from Oil products in NT in 2017. EGA Australia 2018 Table 2.6 equates to 1.7% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value.
E_Total_NT 1860.1502872300002 RE_Total_NT+NRE_Total_NT [GWh] Total production of electricity in Northern Territory in 2010
E_HeatPump 49.72590982 — [GWh] Total production of electricity from Heat pump in NT in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.3% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value.
E_GTurbine 588.587113 — [GWh] Total production of electricity from Gas turbine in NT in 2017. EGA Australia 2018 Table 2.5 equates to 58.7% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value.
E_Total_Aus 230374.0 — [GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5
RE_Total_NT 981.38864359 E_heatpump+E_Lgas+E_solar [GWh] Total production of electricity from renewable energy in Northern Territory in 2010
E_GCombined 253.317061 — [GWh] Total production of electricity from Combined cycle in NT in 2017. EGA Australia 2018 Table 2.5 equates to 38% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value.
TL_Total_Aus 458000000.0 — [m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia
E_Lgas 67.96193097 — [GWh] Total production of electricity from Landfill gas in NT in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.5% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value.
E_Solar 863.7008028 — [GWh] Total production of electricity from Solar in NT in 2017. Department of the Environment and Energy, Australian Energy Statistics, Table O, August 2018, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value.
NRE_Total_NT 878.7616436400001 E_Oil+E_GCombined+E_GTurbine [GWh] Total production of electricity from non-renewable energy in Northern Territory in 2010