Electricity, at powerplant {AU-WA-SWIS}| electricity production mix | AusLCI, U

Unit process v00.00.000

Remark: Production mix for region.. Geography: Western Australia. Technology: Current Version: 2.0 Included processes start:Process begins with electricity supply from different technologies Included processes end: Proces ends with combined supply for regionV Excluded processes:Heat emissions not included. Start date: 2022-08-19 Start date: 2022-08-19 End date: 2022-10-10 Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Generator/publicator: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU

Sector
Energy
Contributor
—
Last updated
10 Oct 2022
Reference ID
e5a99f93-7c2a-3616-8c70-ac76455f1af3

Download this dataset Ask a question about this dataset

Downloads require a free account. You'll be asked to register or sign in.

Documentation

Quantitative reference
Electricity, at powerplant {AU-WA-SWIS}| electricity production mix | AusLCI, U
Sampling procedure
—
Creation date
10 Oct 2022
Is copyright protected
No
Is infrastructure process
No
Tags
energy
Sources
Australian Energy Update 2024
Electricity Gas Australia Highlights FY 2022-23
Greenhouse and energy information by designated generation facility FY 2022-23

Product outputs

Flow AmountUnitComment
Electricity, at powerplant {AU-WA-SWIS}| electricity production mix | AusLCI, U 1.0 kWh —

Technical inputs

Flow AmountUnitComment
Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U 0.008687955989678007 kWh —
Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U 0.008687955989678007 kWh —
Electricity, black coal WA, at power plant {AU}| | AusLCI, U 0.23335757986841815 kWh —
Electricity, high voltage {AU}| electricity production, oil | Cut-off, U 0.0 kWh —
Electricity, high voltage {AU}| electricity production, wind, >3MW turbine, onshore | Cut-off, U 0.2624095659108476 kWh While Australian wind is not off shore, its generally larger installations around 2MW so this inventory was choses over smaller wind turbines
Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U 0.004805846029812991 kWh Landfill gas combustion and sewer gas production if its present in the state
Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U 0.0003780475397379679 kWh Bagasse electricity is used for all biomass energy use
Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U 0.09877163188473055 kWh —
Electricity, low voltage {AU}| electricity production, photovoltaic, 570kWp open ground installation, multi-Si | Cut-off, U 0.053540710000618094 kWh —
Electricity, natural gas, CC, WA, at power plant {AU}| | AusLCI, U 0.12153550801661554 kWh Electricity from combined cycle
Electricity, natural gas, GT, WA, at power plant {AU}| | AusLCI, U 0.21651315475954105 kWh Electricity from gas turbine
Electricity, natural gas, steam, at power plant {AU}| | AusLCI, U 0.0 kWh Electricity from steam gas

Elementary flow outputs

Flow CompartmentSub-compartment AmountUnitComment
Energy losses in electricty transmission Non material emissions— 0.027 kWh —

Parameters

NameValueFormulaDescription
E_BlackCoal 3956.086397 E_BlackCoal_Actual-NGAF_adjust —
E_Solar_Lc 907.67 — [GWh] Total production of electricity from Large-Scale Solar Generation derived from Table O Australian Energy Statistics FY22-23
NGAF_adjust 1393.0 — This factor is used to adjust the electricty mix to meet NGA factors value for 2023.
ExcludeRenewables — — Switch to exclude renewables from the electricity mix. Set parameter to "1" to exclude renewables from this inventory mix. By defaults should be set to "0" to include renewables in the the grid mix.
E_Total_WA 16952.894348795926 RE_Total_WA*I_Re+NRE_Total_WA*I_NRe [GWh] Total production of electricity in Western Australia in FY 2022-23
I_Re 1.0 1-ExcludeRenewables —
E_HeatPump 147.286 — [GWh] Total production of electricity from HeatPump Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
ExcludeNonRenewables — — Switch to exclude non-renewables from the electricity mix. Set parameter to "1" to exclude renewables from this inventory mix. By defaults should be set to "0" to include non-renewables in the the grid mix.
E_Lgas 81.473 — [GWh] Total production of electricity from Lgas Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
E_BlackCoal_Actual 5349.086397 — [GWh] Total production of electricity from BlackCoal Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 4
I_NRe 1.0 1-ExcludeNonRenewables —
SWIS_Solar 1.0 — Percentage of solar generation for SWIS grid based on data split from the Clean Energy Regulator from year 2022-23
E_Oil — — [GWh] Total production of electricity from Oil Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 5
E_Wind_Actual 3055.601647 — [GWh] Total production of electricity from Wind Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 4
E_Solar 2582.13504 (E_Solar_Lc + E_Solar_Sc)*SWIS_Solar —
E_Solar_Sc 1674.46504 — [GWh] Total production of electricity from Small-Scale Solar Generation derived from Table O Australian Energy Statistics FY22-23. The reported GWh reflects the proportion of small-scale solar generation which is sent to grid according to NGA 2023.
SWIS_NG 0.732411683 — Percentage of natural gas power generation for SWIS grid based on data split from the Clean Energy Regulator from year 2022-23
NRE_Total_WA 9686.989661795926 E_BlackCoal+E_Oil+E_NaturalGas [GWh] Total production of electricity from non-renewable resources in Western Australia in FY 2022-23
RE_Total_WA 7265.904686999999 E_Biomass+E_heatpump+E_Lgas+E_Wind+E_solar [GWh] Total production of electricity from renewable resources in Western Australia in FY 2022-23
E_GTurbine 5011.559377 — [GWh] Total production of electricity from GTurbine Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 7
E_NaturalGas 5730.903264795926 (E_GSteam+E_GTurbine+E_Gcombined)*SWIS_NG —
E_GSteam — — [GWh] Total production of electricity from GSteam Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 6
E_Biomass 6.409 — [GWh] Total production of electricity from Biomass Australian electricity generation, by state and territory, renewable energy generation certificates returned in calendar year 2023 (Table 2.10 and Table 2.11)
E_GCombined 2813.142765 — [GWh] Total production of electricity from GCombined Tables 2.4 & Table 2.5 Principal electricity generation by plant type (GWh) - year ending June 2023 1, 8
E_Wind 4448.6016469999995 E_Wind_Actual+NGAF_adjust —