Electricity mix, 2050 Queensland {AU}|_Obsolete | AusLCI, U
Unit process Australia v00.00.000
QLD electricity mix data was inputted into Excel. Gap identified at 2050 by adding up all non-renewable energy sources at 2020. Functions in excel were used to calculate the difference per year for solar, the only scaling renewable in QLD to increase linearly to 2050 estimates (and levelling off to 2080) and for non-renewable sources to decrease constantly to 0 by 2050. Non-scaling renewables were kept constant from 2020 to 2080. Average determined for 2050 and for 2080, values used in parameters within electricity mix 2050 QLD and electricity mix 2080 QLD processes.
- Sector
- Energy
- Contributor
- —
- Last updated
- 30 Dec 1899
- Reference ID
e9a2b625-74d2-351b-9a0a-e0a118bbdb33
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity mix, 2050 Queensland {AU}|_Obsolete | AusLCI, U
- Sampling procedure
- —
- Creation date
- 30 Dec 1899
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Energy Gas Australia 2018/2018/Australian Energy Council.
Energy in Australia 2011/2011/ABARE
State of the energy market 2009/2009/Australian Energy Regulator
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity mix, 2050 Queensland {AU}|_Obsolete | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U | 0.004229909040149953 | kWh | — |
| Electricity, black coal QLD, at power plant {AU}| | AusLCI, U | 0.4049714853022102 | kWh | — |
| Electricity, coal seam methane, at power plant {AU}| | AusLCI, U | 0.010708138833674004 | kWh | — |
| Electricity, coal seam methane, at power plant {AU}| | AusLCI, U | 0.004373746847400208 | kWh | — |
| Electricity, high voltage {AU}| electricity production, oil | Cut-off, U | 0.0005943309230952695 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.002099036704476518 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.00008434375018404268 | kWh | — |
| Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U | 0.011969020588428522 | kWh | — |
| Electricity, high voltage {CO}| treatment of bagasse, from sugarcane, in heat and power co-generation unit, 6400kW thermal | Cut-off, U | 0.00044768657596744977 | kWh | — |
| Electricity, high voltage {RoW}| electricity production, hydro, reservoir, non-alpine region | Cut-off, U | 0.01034455205663276 | kWh | — |
| Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U | 0.49642830825211576 | kWh | — |
| Electricity, natural gas, CC, at power plant {AU}| | AusLCI, U | 0.038351330462932674 | kWh | — |
| Electricity, natural gas, GT, at power plant {AU}| | AusLCI, U | 0.015398110662732604 | kWh | — |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| E_Total_Aus | 230374.0 | — | [GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5 |
| E_HeatPump | 266.0 | — | [GWh] Total production of electricity from Heat pump in QLD in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.4% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_Total_QLD | 62885.5130158 | RE_Total_QLD+NRE_Total_QLD | [GWh] Total production of electricity in Queensland in 2008 |
| TL_Total_Aus | 458000000.0 | — | [m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia |
| E_Biomass | 28.153 | — | [GWh] Total production of electricity from Biomass in QLD in 2017. EGA Australia 2018 Table 2.11-12 equates to 0% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_GCombined | 2411.743091 | — | [GWh] Total production of electricity from Combined cycle in QLD in 2017. EGA Australia 2018 Table 2.5 equates to 4.2% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| NRE_Total_QLD | 29832.707712800002 | E_BlackCoal+E_Oil+E_GTurbine+E_Gcombined+E_CSMGT+E_CSMCC | [GWh] Total production of electricity from non-renewable resources in Queensland in 2008 |
| E_BlackCoal | 25466.83961 | — | [GWh] Total production of electricity from Black coal in QLD in 2017. EGA Australia 2018 Table 2.6 equates to 74.1% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_GTurbine | 968.3180885 | — | [GWh] Total production of electricity from Gas turbine in QLD in 2017. EGA Australia 2018 Table 2.5 equates to 0% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_SGas | 5.304 | — | [GWh] Total production of electricity from Sewage gas in QLD in 2017. EGA Australia 2018 Table 2.11-12 equates to 0% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate 2050 value. |
| E_Solar | 31218.14884 | — | [GWh] Total production of electricity from Solar in QLD in 2017. Department of the Environment and Energy, Australian Energy Statistics, Table O, August 2018 |
| RE_Total_QLD | 33052.805303 | E_Hydro+E_Biomass+E_Bagasse+E_heatpump+E_Lgas+E_SGas+E_solar | [GWh] Total production of electricity from renewable resources in Queensland in 2008 |
| E_CSMGT | 275.0453143 | — | [GWh] Total production of electricity from CSM GT in Australia in 2017. EGA Australia 2018 able 2.6 equates to 7.2% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Hydro | 650.522463 | — | [GWh] Total production of electricity from Hydro in QLD in 2017. EGA Australia 2018 Table 2.6 equates to 1.5% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_Oil | 37.374805 | — | [GWh] Total production of electricity from Oil products in QLD in 2017. EGA Australia 2018 Table 2.6 equates to 0% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_CSMCC | 673.386804 | — | [GWh] Total production of electricity from CSM CC in Australia in 2017. EGA Australia 2018 Table 2.6 equates to 8.6% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value. |
| E_Bagasse | 752.678 | — | [GWh] Total production of electricity from Bagasse in QLD in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.8% of supply, 2017 value used for 2050 calculations, remains constant. |
| E_Lgas | 131.999 | — | [GWh] Total production of electricity from Landfill gas in QLD in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.1% of supply, 2017 value used for 2050 calculations, remains constant. |