Electricity mix, 2080 South Australia {AU}|_Obsolete | AusLCI, U
Unit process Australia v00.00.000
SA electricity mix data was inputted into Excel. Two categories of renewables identified, scaling (Solar and Wind) and non-scaling (Heat Pump and Lgas). Gap identified at 2050 by sum of all non-renewable energy sources. Scaling renewable percentage was multiplied by 2050 gap to find the 2050 value for each scaling renewable. Using a linear excel function, years 2021 to 2050 were calculated and the 2050 values were held constant for 2050 to 2080. Functions in excel were used for non-renewable sources to decrease to 0 by 2050. Non-growing renewables were kept constant from 2020 to 2080. The average for each energy source was determined for 2050 and 2080 and are the values used in parameters within the electricity mix 2050 SA and electricity mix 2080 SA processes. Remark: Production mix for region.. Geography:South Australia. Technology: Current Version: 1.0 Included processes start:Process begins with electricity supply from different technologies Included processes end: Proces ends with combined supply for regionV Excluded processes:Heat emissions not included. Start date:2011-07-0 End date:2102-06-30 is data valid for entire period: false Record: Data entry by: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU Generator: Generator/publicator: Tim Grant Telephone: 0061 408104977; E-mail: tim@lifecycles.com.au; Company: LCS; Country: AU
- Sector
- Energy
- Contributor
- —
- Last updated
- 04 Jul 2013
- Reference ID
f818a0b3-4a32-33f3-b64c-9ff91fe0ae15
Download this dataset Ask a question about this dataset
Downloads require a free account. You'll be asked to register or sign in.
Documentation
- Quantitative reference
- Electricity mix, 2080 South Australia {AU}|_Obsolete | AusLCI, U
- Sampling procedure
- —
- Creation date
- 04 Jul 2013
- Is copyright protected
- No
- Is infrastructure process
- No
- Tags
- energy
- Sources
-
Energy Gas Australia 2018/2018/Australian Energy Council.
Energy in Australia 2011/2011/ABARE
State of the energy market 2009/2009/Australian Energy Regulator
Product outputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity mix, 2080 South Australia {AU}|_Obsolete | AusLCI, U | 1.0 | kWh | — |
Technical inputs
| Flow | Amount | Unit | Comment |
|---|---|---|---|
| Electricity, at heat pump 30kW, allocation electricity/CH U/adapted {AU}| | AusLCI, U | 0.003608259938802393 | kWh | — |
| Electricity, high voltage {AU-VIC}| market for electricity, high voltage | AusLCI, U | 0.21303254943364933 | kWh | — |
| Electricity, high voltage {AU}| electricity production, oil | Cut-off, U | 0.0004145983721129443 | kWh | — |
| Electricity, high voltage {AU}| electricity production, wind, >3MW turbine, onshore | Cut-off, U | 0.5455358986075837 | kWh | — |
| Electricity, high voltage {AU}| heat and power co-generation, biogas, gas engine | Cut-off, U | 0.0006790731082478007 | kWh | Landfill gas combustion and sewer gas production if its present in the state |
| Electricity, low voltage {AU}| electricity production, photovoltaic, 3kWp slanted-roof installation, multi-Si, panel, mounted | Cut-off, U | 0.13655408304805886 | kWh | — |
| Electricity, natural gas, CC, SA,at power plant {AU}| | AusLCI, U | 0.03835308938493675 | kWh | Electricity from combined cycle |
| Electricity, natural gas, GT, at power plant {AU}| | AusLCI, U | 0.01014951845701191 | kWh | Electricity from gas turbine |
| Electricity, natural gas, steam, SA, at power plant {AU}| | AusLCI, U | 0.05174354139008169 | kWh | Electricity from steam gas |
Parameters
| Name | Value | Formula | Description |
|---|---|---|---|
| E_Wind | 7725.852597 | — | [GWh] Total production of electricity from Wind in SA in 2017. EGA Australia 2018 Table 2.6 equates to 19.9% of supply, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate average of 2020-2080 value. |
| Import_fr_Vic | 3015.9565 | Import_Fr_vic_ALCI/NGAF_Adjust | — |
| Import_Fr_vic_ALCI | 3015.9565 | — | [GWh] Total production of electricity from Import from Victorian grid in NSW in 2017. EGA Australia 2018 Table 2.5 equates to 2.3% of supply |
| E_Lgas | 9.617 | — | [GWh] Total production of electricity from Landfill gas in SA in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.1% of supply, 2017 value used for 2020-2080 calculations, remains constant. |
| E_GSteam | 732.7894913 | — | [GWh] Total production of electricity from Steam from gas in SA in 2017. EGA Australia 2018 Table 2.5 equates to 15.6% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value and average taken for 2020-2080. |
| NGAF | 1.0 | — | Forces database to be NGA factor compliant for electricity and energy from different fuel types. Not currently compliant with liquid fossil fuel scope 3 emissions |
| E_Total_SA | 14161.950875679 | RE_Total_SA+NRE_Total_SA+import_Fr_Vic | [GWh] Total production of electricity in South Australia in 2008 |
| E_HeatPump | 51.1 | — | [GWh] Total production of electricity from Heat pump in SA in 2017. EGA Australia 2018 Table 2.11-12 equates to 0.3% of supply, 2017 value used for 2020-2080 calculations, remains constant. |
| E_GCombined | 543.1545678 | — | [GWh] Total production of electricity from Combined cycle in SA in 2017. EGA Australia 2018 Table 2.5 equates to 26% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value and average taken for 2020-2080. |
| NRE_Total_SA | 1425.552562679 | E_Oil+E_GSteam+E_GTurbine+E_GCombined | [GWh] Total production of electricity from non-renewable resources in South Australia in 2008 |
| NGAF_Adjust | 1.0 | — | Factor used to adjust imported GWh |
| RE_Total_SA | 9720.441813 | E_heatpump+E_Lgas+E_Wind+E_solar | [GWh] Total production of electricity from Renewable resources in South Australia in 2008 |
| E_Total_Aus | 230374.0 | — | [GWh] Total Electricity production in Australia in 2010 - ESAA 2011 table 2.5 |
| E_Oil | 5.871521779 | — | [GWh] Total production of electricity from Oil products in SA in 2017. EGA Australia 2018 Table 2.6 equates to 0.1% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value and average taken for 2020-2080. |
| TL_Total_Aus | 458000000.0 | — | [m] Total length of transmission lines, overhead lines and underground cables (from 500kV to 11kV) in Australia |
| E_Solar | 1933.872216 | — | [GWh] Total production of electricity from Solar in SA in 2017. Department of the Environment and Energy, Australian Energy Statistics, Table O, August 2018, Value is calculated by percentage of gap for renewable sources for 2050 and linear model used to calculate average of 2020-2080 value. |
| E_GTurbine | 143.7369818 | — | [GWh] Total production of electricity from Gas turbine in SA in 2017. EGA Australia 2018 Table 2.5 equates to 1.9% of supply, Percent of electricity mix goes to 0 by 2050, linear model used to calculate value and average taken for 2020-2080. |